Безплатна доставка със Speedy над 129 лв
Box Now 9 лв Speedy office 11 лв Speedy 13 лв ЕКОНТ 6 лв Еконтомат/Офис на Еконт 6 лв

Implementation of New Scheme on Indian Power System for Distance Relay Operation in Zone 3 to Avoid Power System Blackout

Език Английски езикАнглийски език
Книга С меки корици
Книга Implementation of New Scheme on Indian Power System for Distance Relay Operation in Zone 3 to Avoid Power System Blackout Muhammah Adnan
Код Либристо: 15844031
Издателство Grin Publishing, февруари 2017
Thesis (M.A.) from the year 2016 in the subject Energy Sciences, grade: Master's Degree, Hohai Unive... Цялото описание
? points 147 b
116 лв
Външен склад Изпращаме след 14-18 дни

30 дни за връщане на стоката


Може би ще Ви заинтересува


Trust Economy PHILIPP K DIEKHONER / С меки корици
common.buy 42 лв
Statistique Administrative Et Medicale de l'Asile Public Des Alienes de Lille L HERBON DE LUSSAST- / С меки корици
common.buy 38 лв
Islam im Morgen- und Abendland August Müller / С меки корици
common.buy 149 лв
Cuaderno práctico de ejercicios antiestrés RUT ABADIA / С меки корици
common.buy 23 лв
Child Language Reader Kate Trott / С меки корици
common.buy 100 лв
Lehrbuch Des B rgerlichen Rechtes Bernhard Matthiaß / С меки корици
common.buy 155 лв

Thesis (M.A.) from the year 2016 in the subject Energy Sciences, grade: Master's Degree, Hohai University (Energy and Electrical Collage), course: Electric Power system, language: English, abstract: In July 2012 there was blackout in India. As the result of this disturbance there were two blackouts. In first blackout only the Northern Grid was affected but in the second blackout Northern, Eastern and North-Eastern grid collapsed. A committee formed by the government analyzed the events that resulted in the collapse of system and pointed out no of factors that lead to disturbance. Whole grid collapsed under load encroachment condition. In this thesis different factors have been analyzed using PSCAD simulation and solutions have been proposed. Approximate model of Indian power system has been developed in PSCAD using approximate parameters given in Grid Failure Report issued by the Indian government. Increase in installed capacity of power system and its impact on system frequency and rotor angle has been studied. A new algorithm has been proposed for distance relay operation in Zone 3 to avoid power system blackout using Indian grid model. One of the main factors that lead to the collapse of whole system was the operation of zone 3 distance relay on 400kV Bina-Gwalior Line. This scheme will improve system stability under heavy load conditions. A simplified model in PSCAD was established in order to study the zone 3 protection of distance relay.

Информация за книгата

Пълно заглавие Implementation of New Scheme on Indian Power System for Distance Relay Operation in Zone 3 to Avoid Power System Blackout
Автор Muhammah Adnan
Език Английски език
Корици Книга - С меки корици
Дата на издаване 2017
Брой страници 62
Баркод 9783668386563
ISBN 3668386560
Код Либристо 15844031
Издателство Grin Publishing
Тегло 91
Размери 148 x 210 x 4
Подарете тази книга днес
Лесно е
1 Добавете книгата в количката си и изберете Доставка като подарък 2 В замяна ще ви изпратим ваучер 3 Книгата ще пристигне на адреса на получателя

Вход

Влезте в акаунта си. Още нямате акаунт за Libristo? Създайте го сега!

 
задължително
задължително

Нямате акаунт? Използвайте предимствата на акаунта за Libristo!

Благодарение на акаунта за Libristo държите всичко под контрол.

Създаване на акаунт за Libristo